MFP OPTIONS: B064 SERIES
B064 Series/B140 Series/G126 1-88 SM
1.16.4 USB 2.0 (B525-01)
ACCESSORY CHECK
Check the accessories and their quantities against this list:
Description Q’ty
1. USB 2.0 PCB......................................................................... 1
Installation Procedure
CAUTION
Switch the machine off and unplug the machine before starting the
following procedure.
1. Remove the rear upper cover ( x 2).
2. Remove the controller cover ( x 9).
3. Remove the slot cover [A] ( x 2).
4. Insert the USB board [B] into the PCI slot.
5. Fasten the slot cover to the USB board ( x 2).
6. Use SP5990-005 to print a Self-Diagnostic Report with the system settings and
confirm that the machine correctly recognizes the interface.