3000 SHEET FINISHER (B478/B706)
SM 1-65 B064 Series/B140 Series/G126
Installation
1.12.2 INSTALLATION
CAUTION
Unplug the machine power cord before starting the following procedure.
1. Unpack the finisher and remove all tapes and shipping retainers.
2. Open the front door and remove the shipping retainers. Remove brackets [A],
[B], and [C] ( x 2 each).
3. Install the front joint bracket [D] and rear joint bracket [E] ( x 2 each) (M4 x
14) on the left side of the copier.
4. Remove the connector cover [F].