FUSING UNIT
B064/B140 Series/G126 3-76 SM
Important Notes about Fusing Unit Assembly (B064 Series)
Follow these important guidelines when re-assembling the fusing unit:
Use the external holes to fasten the screws when you fasten the lower guide
plate. The inner screws are adjusted to correct wrinkling.
Handle the fusing lamps carefully to prevent breaking them; avoid touching them
with bare hands.
Match colors of the bayonet connectors with the colors of the terminals when
reconnecting them to the bracket at [A] and [B]. If either connection is incorrect,
the machine cannot control the temperature of the hot roller and an SC is logged
as soon as the machine is powered on.
The discharge brush [C] on the fusing terminal bracket should contact the inner
surface of the hot roller.
Check that there is some play [D] (in the direction indicated by the arrows) in the
positioning of the fusing lamps.
B140R998.WMF
B140R997.WMF
[A]
[B]
[C]
[D]