LASER UNIT
SM 3-29 B064 Series/B140 Series/G126
Replacement
Adjustment
3.5.3 LASER SYNCHRONIZATION DETECTOR REPLACEMENT
Remove the right side cover ( x 2)
NOTE: If the optional LCT is installed, disconnect it ( x 1).
[A]: Development unit fans ( x 4, x 1)
[B]: Synchronization detector ( x 1, x 1)
After replacement, set SP1002-001~007 (Side-to-Side Registration) to the defaults.