MAIN MACHINE (G126)
SM 1-119 B064 Series/B140 Series/G126
Installation
6. Open the front door, open the toner
bottle holder [C], then remove all tape
and shipping retainers.
7. Remove the PCU inner cover [D] (2
screws) and disconnect the fan motor
[E] (1 connector).
8. Lower the transfer unit by turning its
knob [A].
9. Remove the bracket [B], and the red
tag from the transfer belt (1 screw).
10. Remove the pin [C], and the red tag
from the cleaning plate.
B064I007.WMF
B064I008.WMF
B140I009.WMF
[C]
[A]
[B]
[C]
[D]
[E]
Rev. 05/2005