DEVELOPMENT UNIT
B064 Series/B140 Series/G126 3-48 SM
10. Re-assemble the machine.
Hold the hopper perfectly level when re-attaching it, to prevent toner from
entering the rails of the development filter.
NOTE: Automatic process control starts automatically after the machine is
switched on, so after replacing the developer, you should enter the SP
mode and initialize the developer with SP2801 as soon as possible
after switching the machine on.
11. Do SP2801 (TD Sensor Initial Setting).
B064 Series
Switch the machine on.
Press Clear Modes
On the operation panel keypad, press .
Hold down Clear/Stop for more than 3 seconds.
Press “Copy SP” on the touch-panel.
Press .
Read the lot number from the package, enter the number, then press .
Press Execute.
B140 Series
Open the front door.
Important: If you open the front door, auto process control will not start.
SP2801 must be done before auto process control starts.
Turn the machine on.
Push Clear Modes
On the operation panel keypad, push .
Hold down Clear/Stop for more than 3 seconds.
Push “Copy SP” on the touch-panel.
Push .
Read the lot number from the pack of developer, input the number, then
push .
Push Execute.