B064 SERIES SERVICE MODE
B064 Series/B140 Series/G126 4-14 SM
SC No. Symptom Possible Cause
CIS auto adjust error 183 D
Automatic adjustment of the CIS
unit failed.
CIS unit defective.
CIS exposure glass dirty.
White roller dirty or installed incorrectly.
PSU power supply (+5V, –12V) is
abnormal.
IPU defective
CIS transmission error 184 D
When the CIS is powered on, the
ADF detects one of the following
abnormal conditions on the CIS
unit:
The SOUT signal does not go
high within 1 s after power on.
The SOUT signal goes high
within 1 s after power on, but the
SBU ID cannot be read after 3
attempts.
CIS unit defective.
Harness between the CIS, ADF is
disconnected.
PSU power (5V) is abnormal.
BCU, IPU defective