B140 SERIES AND G126 SERVICE MODE
B064 Series/B140 Series/G126 4-64 SM
Scanner image setting error 953 D
The settings required for image
processing using the scanner are
not sent from the IPU.
• Software defective
Printer image setting error 954 D
The settings required for image
processing using the printer
controller are not sent from the IPU.
• Software defective
Memory setting error 955 D
The settings that are required for
image processing using the
memory are not sent from the IPU.
• Software defective
Printer ready error 964 D
The print ready signal is not
generated for more than 17
seconds after the IPU received the
print start signal.
• Software defective
Print image data transfer error 984 D
After a data transfer begins from
the controller to the engine via the
PCI bus, the transfer does not end
within 15 s.
• Controller (SIMAC) board defective
• BICU defective
• BICU Ù controller disconnected
Scanned image data transmission error 985 D
After a data transfer begins from
the engine to the controller via the
PCI bus, the transfer does not end
within 3 s.
• Controller (SIMAC) board defective
• BICU defective
• BICU Ùcontroller disconnected
Software error 1 986 D
The write parameter received by
the write module at the beginning of
the setting table is NULL.
• Controller (SIMAC) board defective
• BICU defective
• BICU Ùcontroller disconnected
Software error 2 990 D
The software performs an
unexpected function and the
program cannot continue.
• Software defective, re-boot
*1
Software error 3 991 C
The software performs an
unexpected function and the
program cannot continue. However,
unlike SC990, recovery processing
allows the program to continue.
• Software defective, re-boot
*1
*1
: In order to get more details about SC990 and SC991:
3) Execute SP7403 or print an SMC Report (SP5990) to read the history of the 10 most recent
logged errors.
4) If you press the zero key on the operation panel with the SP selection menu displayed, you
will see detailed information about the recently logged SC990 or SC991, including the
software file name, line number, and so on. 1) is the recommended method, because