EasyManua.ls Logo

Ricoh B064 - Page 454

Ricoh B064
1060 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE PROGRAM MODE TABLES
B064 Series/B140 Series/G126 5-52 SM
2968 Toner Exit Mode
Press Execute to force used toner into the toner collection bottle. The moving parts
of the cleaning and toner collection areas will turn for about 60 s with the transfer
belt released.
2969* Toner Bottle Revolution Count
001 Copy Count Setting
Sets the standard number of copies by using the
number of toner bottle rotations. DFU
[50~500/1]
002 Count Reset
Press “Execute” to reset the toner bottle rotation count.
DFU
003 Copy Count Display 1
004 Copy Count Display 2
005
Copy Count Display 3
006
Copy Count Display 4
007
Copy Count Display 5
008
Copy Count Display 6
009
Copy Count Display 7
Used to check the number of toner bottle rotations.
2970* Transfer Belt Resistance: Disp. Current Value
Displays the resistance of the transfer belt and displays this value (M). DFU
2971* Trans. Interval Output
001 Voltage
002 Current
Displays the measurement condition of the value in
SP2970.
2972* Toner Bottle Cool. Fan Drive Control
Switches fan control On/Off.
[0~1/1]
0: Off. The toner bottle fan switches off when the machine is powered off and
when the machine enters the night mode.
1: On: Toner bottle fan remains on.
Switch on in an extremely hot environment to prevent the toner from overheating
and clumping.