SERVICE PROGRAM MODE TABLES
B064 Series/B140 Series/G126 5-52 SM
2968 Toner Exit Mode
Press Execute to force used toner into the toner collection bottle. The moving parts
of the cleaning and toner collection areas will turn for about 60 s with the transfer
belt released.
2969* Toner Bottle Revolution Count
001 Copy Count Setting
Sets the standard number of copies by using the
number of toner bottle rotations. DFU
[50~500/1]
002 Count Reset
Press “Execute” to reset the toner bottle rotation count.
DFU
003 Copy Count Display 1
004 Copy Count Display 2
005
Copy Count Display 3
006
Copy Count Display 4
007
Copy Count Display 5
008
Copy Count Display 6
009
Copy Count Display 7
Used to check the number of toner bottle rotations.
2970* Transfer Belt Resistance: Disp. Current Value
Displays the resistance of the transfer belt and displays this value (MΩ). DFU
2971* Trans. Interval Output
001 Voltage
002 Current
Displays the measurement condition of the value in
SP2970.
2972* Toner Bottle Cool. Fan Drive Control
Switches fan control On/Off.
[0~1/1]
0: Off. The toner bottle fan switches off when the machine is powered off and
when the machine enters the night mode.
1: On: Toner bottle fan remains on.
Switch on in an extremely hot environment to prevent the toner from overheating
and clumping.