SERVICE PROGRAM MODE TABLES
SM 5-59 B064 Series/B140 Series/G126
Service
Tables
4428 TBD
4600* Read SBU ASIC ID
Displays the SBU ID code confirmed by reading the SBU after the SBU adjusts
automatically at power on.
[0~FFFFh/1]
4601* SBU PLL Adjustment
Adjusts the PLL bandwidth. DFU
[0~FFFFh/1]
4605 Scanner Adjustment
001* Flag Display
Displays a flag to indicate whether density control adjustment was executed with
the standard white board for the CCD.
[0~1/1]
0: Not executed.
1: Executed
002 Start
Starts the density adjustment for the CCD using the standard white board. Place
5 sheets of A3 plain paper on the exposure glass, then press Execute. A
message is displayed to indicate the success or failure of the adjustment. DFU
4610* White Level Adj: Next
4613* White Level Adj.: Previous Normal
4616* White Level Adj.: Factory
4624* Read Offset Data
4632* Gain Adjustment DFU
4641* White Adjust Loop
4646* SBU Adjustment Error Flag
4647* SBU Hard Error Flag
4662* Gain Adjustment Normally
4681* Gain Adjustment at Factory
4691* Read Shading Data
4694* Black Level
4700* Read CIS ASIC ID
Reads and displays the ID of the CIS board at power.
4701* Frequency Adjust DFU
4702* Periodic Adjustment Setting