SERVICE PROGRAM MODE TABLES
B064 Series/B140 Series/G126 5-96 SM
5907* Plug & Play Maker/Model Name
Selects the brand name and the production name for Windows Plug & Play. This
information is stored in the NVRAM. If the NVRAM is defective, these names
should be registered again.
After selecting, press the “Original Type” key and “#” key at the same time. When
the setting is completed, the beeper sounds five times.
5913 Switchover Permission Time
002 Print Application Timer
Sets the length of time to elapse before allowing another application to take
control of the display when the application currently controlling the display is not
operating because a key has not been pressed.
[3~30/1 s]
102 Print Application Set
5914* Application Counter Display
Selects the total counts that will be displayed in the UP mode.
001 Print Counter
003 Copier Counter
[0~1/1]
0: Not displayed
1: Displayed
5915* Mechanical Counter Detection
Displays whether the mechanical counter is installed in the machine.
[0~2/1]
0: Not detected.
1: Detected
2: Unknown
5918* A3/DLT Counter Display
Determines whether pressing the counter key displays count confirmation:
system initial settings system manager settings counter
[0~1/1]
0: No display
1: Display
This SP affects the display only, and has no effect on SP5104 (A3/DLT Double
Count).