IMAGE FUSING AND PAPER EXIT
B064 Series/B140 Series/G126 6-124 SM
Here is a list of SC codes issued if a fusing unit error occurs. For details, see
“Troubleshooting”.
SC541 Fusing thermistor open
SC542 Fusing temperature warm-up error
SC543 Fusing lamp overheat error 1 (software)
SC544 Fusing lamp overheat error 1 (hardware)
SC545 Fusing lamp overheat error 2
NOTE: To release these machine after one of these SC codes is issued, just enter
the SP mode.
Temp.
o
C
200
o
C
Main SW ON
Before Rotation
70 s
After Warm-up
185
o
C
200
o
C
Power On (Below 100
o
C)
Power On (Above 100
o
C)
Control Temperature: 185
o
C
Warm-up Temperature: 182
o