1004 019 Reverse: LS: CCW *EGB
Adjusts the inverter motor speed.
[-4.00 to 4.00 / 0.0 / 0.01%/step]
1004 020 Reverse: RS: CCW *EGB
1004 021 DEV / OPC [K]: LS: N2 *EGB Adjusts the black development and OPC motor
speed.
[-4.00 to 4.00 / -1.35 / 0.01%/step]
1004 022 DEV / OPC [K]: RS: N2 *EGB
1004 023 DEV [CMY]: LS: N2 *EGB
Adjusts the color development motor speed.
[-4.00 to 4.00 / 0.0 / 0.01%/step]
1004 024 DEV [CMY]: RS: N2 *EGB
1004 025 OPC [CMY]: LS: N2 *EGB
Adjusts the color OPC motor speed.
[-4.00 to 4.00 / -1.35 / 0.01%/step]
1004 026 OPC [CMY]: RS: N2 *EGB
1004 027 Fusing: LS: N2 *EGB
Adjusts the paper exit and fusing motor speed.
[-4.00 to 4.00 / 0.6 / 0.01%/step]
1004 028 Fusing: RS: N2 *EGB
1004 029 Trans. Belt: LS: N2 *EGB
Adjusts the transfer belt motor speed.
[-4.00 to 4.00 / 0.0 / 0.01%/step]
1004 030 Trans. Belt: RS: N2 *EGB
1004 031 PFU: LS: Normal 2 *EGB Adjusts the speed of the feed motor in the
optional paper tray unit.
[-4.00 to 4.00 / -1.14 / 0.01%/step]
1004 032 PFU: RS: Normal 2 *EGB
1004 033 Duplex: LS: Add: N2 *EGB
Adjusts the duplex motor speed.
[-4.00 to 4.00 / 0.0 / 0.01%/step]
1004 034 Duplex: RS: Add: N2 *EGB
1004 035 Duplex: LS: N2 *EGB
Adjusts the duplex motor speed.
[-4.00 to 4.00 / -0.36 / 0.01%/step]
1004 036 Duplex: RS: N2 *EGB
1004 037 Reverse: LS: CW: N2 *EGB
Adjusts the inverter motor speed.
[-4.00 to 4.00 / 0.6 / 0.01%/step]
1004 038 Reverse: RS: CW: N2 *EGB
1004 039 Rever.: LS: CCW: N2 *EGB
Adjusts the inverter motor speed.
[-4.00 to 4.00 / 0.0 / 0.01%/step]
1004 040 Rever.: RS: CCW: N2 *EGB
1004 041 DEV / OPC [K]: LS: TC *EGB
Adjusts the black development and OPC motor
speed.
[-4.00 to 4.00 / -1.35 / 0.01%/step]
5. Service Tables