1911 026 Duplex Temp. 2 *EGB [0 to 200 / 5 / 1deg /step]]
1911 027 Duplex Temp.: S1 *EGB
This SP keeps the target print temperature for
specified printouts with this SP in duplex printing.
[0 to 500 / 80 / 1 sheet/step]
1911 028 Duplex Temp.: S2 *EGB
This SP controls when the temperature reduction of
SP1911-025 is done.
[0 to 500 / 10 / 1 sheet/step]
1911 029 Duplex Temp.: S3 *EGB
This SP controls when the temperature reduction of
SP1911-026 is done.
[0 to 500 / 15 / 1 sheet/step]
1911 040 Dec.Tmp Keep Time *EGB
Keeps the temperature reduction for the time
specified with this SP even the process control
interrupts the multiple printing job.
[0 to 500 / 60 / 1 sec/step]
1912
[Fusing Rotat.] Fusing Unit Roller Rotation Control
Paper Type -> TC1: Thick paper 1, TC2: Thick paper 2, OHP, SP: Special, GL: Glossy
paper
1912 001
Rotation *EGB
[0 or 1 / 1 / -]
0: Off 1: On.
When the printer is in the ready condition, the nip between the hot roller and pressure
roller is in the same position. This may cause deformation of the rollers. Therefore, a
temporary rotation prevents this problem. SP 1912 001 turns this feature on or off.
SP1912-003 and 004 control this rotation.
Pre-rotation: Fusing idling
1912 002
Prerotat. Speed *EGB [0 to 2 / 2 / -]
Adjusts the speed of the fusing-unit rollers during fusing idling.
0: Regular speed, 1: Low speed, 2: 1/3 regular speed
1912 003
Rotation Freque. *EGB [1 to 24 / 4 / 1 hour/step]
Adjusts the frequency of the fusing-unit roller rotation if the machine is in the ready
condition for a very long interval.
1912 004
Rotation Inter. *EGB [0 to 25 / 0.1 / 0.1 sec/step]