Adjusts the duration of the fusing-unit roller rotation
1912 005
Prerotat. Temp. *EGB [0 to 200 / 100 / 1deg /step]
Fusing idling is not done if the fusing unit temperature is above this value.
1912 006
Prerotat. Inter. *EGB [0 to 180 / 1 / 1 min/step]
Adjusts the duration of fusing idling immediately after the power is turned on.
1912 007
Ex. Rotation Time *EGB [0 to 10 / 5 / 1 sec/step]
Adjusts the time for extra rotation of the fusing unit rollers at the end of a job. If the fusing
motor stops before the fusing lamp turns off, the temperature can become very high.
1912 008
Prerotat. Ext. *EGB [0 to 255 / 0 / 1 sec/step]
Adjusts the additional time for pre-rotation of the fusing rollers.
1912 010
TC1: Rotat. Ext. *EGB [0 to 255 / 10 / 1 sec/step]
Adjusts the additional time of the fusing roller pre-rotation for thick paper 1.
1912 011
TC2 Rotat. Ext. *EGB [0 to 255 / 15 / 1 sec/step]
Adjusts the additional time of the fusing roller pre-rotation for thick paper 2.
1912 012
OHP: Rotat. Ext. *EGB [0 to 255 / 15 / 1 sec/step]
Adjusts the additional time of the fusing roller pre-rotation for OHP.
1912 013
SP: Rotat. Ext. *EGB [0 to 255 / 15 / 1 sec/step]
Adjusts the additional time of the fusing roller pre-rotation for special paper.
1912 014
GL: Rotat. Ext. *EGB [0 to 255 / 10 / 1 sec/step]
Adjusts the additional time of the fusing roller pre-rotation for glossy paper.
1912 015
LL: RotSpd. Sel *EGB
[0 or 1 / 1 / 1]
0: OFF, 1: ON
Turns on or off the rotation speed switching of the pre-rotation in LL condition.
When the "ON" is set, pre-rotation speed is the one-third of normal speed.
1912 016
LM: RotSpd. Select *EGB
[0 or 1 / 1 / 1]
0: OFF, 1: ON
Turns on or off the rotation speed switching of the pre-rotation in LM condition.