When the "ON" is set, pre-rotation speed is the one-third of normal speed.
1912 017
MM/HH: RotSpd. Sel *EGB
[0 or 1 / 1 / 1]
0: OFF, 1: ON
Turns on or off the rotation speed switching of the pre-rotation in MM/HH condition.
When the "ON" is set, pre-rotation speed is the one-third of normal speed.
1913 [Heating Roller] Heating Roller Control
1913 002
Stand-by Temp. *EGB [0 to 200 / 150 / 1deg /step]
Adjusts the heating roller temperature when the machine is in the ready condition.
1916 [Nip Measure] Fusing Nip Width Measurement DFU
1916 001
Nip Measure Exe.
[0 or 1 / 0 /-]
0: Not execute, 1: Execute
Performs the nip width measurement.
1916 002
Prerotation Time *EGB [0 to 60 / 10 / 1 sec/step]
Adjusts the rotation time of the fusing unit rollers before the nip measurement.
1917
[Environ. Adapt.] Fusing Idling: Environment Correction
The machine automatically adjusts the duration of fusing idling, depending on room
temperature measured by the temperature/humidity sensor
(Paper Type, Temperature Environment, Value of Temperature/ Rotation Time)
Paper Type N1: Plain paper 1, N2: Plain paper 2, T1: Thick paper 1, T2: Thick paper
2, SP: Special (see the Specifications table for details on these paper weights)
Temperature Environment -> H: High temperature, L: Low temperature
Value of Temperature/ Time: Dec.: Decrease, Inc.: Increase
1917 001 LL/MM Border *EGB
Adjusts the threshold degree between LL (Low
temperature and Low humidity) and MM (Middle
temperature and middle humidity).
[0 to 35 / 23 / 1deg /step]
1917 002 LM Temp Adj. *EGB
Adjusts the additional temperature for LM
condition. This temperature is added to the fusing
temperature of MM condition.