2111 [Manual Execut.] Manual Line Position Adjustment Execution
2111 001 Position Adjust. Performs the line position adjustment.
2111 002 Pro. Position Adj. Performs an approximate line position adjustment.
2111 003 Skew Adjust. Performs the skew adjustment.
2111 004 ID S. Adjust. Tests the ID sensor.
2111 005 Area.Magni.Clr. Clears the area magnification setting.
2120 [LD Off Check] Displays the LD off check state.
2143
[ID S. Display] ID Sensor Display
The ID sensor assembly has three sensors: Left, Center, Right
2143 001 PWM: Left *EGB
Displays the PWM value for each sensor.
[0 to 512 / 0 / 1/step]
2143 002 PWM: Center *EGB
2143 003 PWM: Right *EGB
2143 004 Avg: Left *EGB
Displays the average output from each sensor.
[0.00 to 5.00 / 0.00 / 0.01 volt/step]
2143 005 Avg: Center *EGB
2143 006 Avg: Right *EGB
2143 007 Max: Left *EGB
Displays the maximum output from each sensor.
[0.00 to 5.00 / 0.00 / 0.01 volt/step]
2143 008 Max: Center *EGB
2143 009 Max: Right *EGB
2143 010 Min: Left *EGB
Displays the minimum output from each sensor.
[0.00 to 5.00 / 0.00 / 0.01 volt/step]
2143 011 Min: Center *EGB
2143 012 Min: Right *EGB
2143 013 Max2: Left *EGB
Displays the maximum 2 output from each sensor.
[0.00 to 5.00 / 0.00 / 0.01 volt/step]
2143 014 Max2: Center *EGB
2143 015 Max2: Right *EGB
2143 016 Min2: Left *EGB
Displays the maximum 2 output from each sensor.
Service Mode Table