2201 003 RS: [C] *EGB
2201 004 RS: [Y] *EGB
2201 006 LS: [K] *EGB
2201 007 LS: [M] *EGB
2201 008 LS: [C] *EGB
2201 009 LS: [Y] *EGB
2202
[Charge Bias: AC] Charge Roller Voltage: AC
(Process Speed, [Color]) Process Speed -> LS: Low speed, RS: Regular speed
These SPs adjust the AC voltage of the drum charge roller. These are used only when
SP2-202-011 is set to "1".
2202 001 RS: [K] *EGB
[0 to 3000 / 2000 / 1 V/step]
2202 002 RS: [M] *EGB
2202 003 RS: [C] *EGB
2202 004 RS: [Y] *EGB
2202 006 LS: [K] *EGB
2202 007 LS: [M] *EGB
2202 008 LS: [C] *EGB
2202 009 LS: [Y] *EGB
2202 011 Output Control *EGB
Selects the method for the charge roller AC bias
adjustment.
[0 or 1 / 0 / -]
0: Process Control, 1: Setting
2202 012 Interval *EGB
Adjusts the interval for charge roller AC bias
adjustment.
[0 to 2000 / 210 / 1 sheet/step]
2203
[Charge Bias: AC] Charge Roller Voltage: AC/I
(Process Speed, [Color]) Process Speed -> LS: Low speed, RS: Regular speed
5. Service Tables
182