These SPs adjust the AC/I bias of the drum charge roller. These are used only when
SP3-501-001 is set to “1”.
2203 001 RS: [K] *EGB [0 to 1.5 / 0.30 / 0.01 mA/step]
2203 002 RS: [M] *EGB [0 to 1.5 / 0.30 / 0.01 mA/step]
2203 003 RS: [C] *EGB [0 to 1.5 / 0.30 / 0.01 mA/step]
2203 004 RS: [Y] *EGB [0 to 1.5 / 0.30 / 0.01 mA/step]
2204
[Charge Bias] Charge Roller Voltage: Corrections for humidity
(Environmental correction, [Color])
For more about the humidity conditions, see SP 2304.
Adds these environment correction coefficients to the charge bias.
2204 001 Environ. : HH: [K] *EGB [0 to 255 / 204 / 1/step]
2204 002 Environ. : HH: [M] *EGB [0 to 255 / 196 / 1/step]
2204 003 Environ. : HH: [C] *EGB [0 to 255 / 197 / 1/step]
2204 004 Environ. : HH: [Y] *EGB [0 to 255 / 191 / 1/step]
2204 006 Environ. : H: [K] *EGB [0 to 255 / 197 / 1/step]
2204 007 Environ. : H: [M] *EGB [0 to 255 / 188/ 1/step]
2204 008 Environ. : H: [C] *EGB [0 to 255 / 190 / 1/step]
2204 009 Environ. : H: [Y] *EGB [0 to 255 / 183 / 1/step]
2204 011 Environ. : MM: [K] *EGB [0 to 255 / 187 / 1/step]
2204 012 Environ. : MM: [M] *EGB [0 to 255 / 179 / 1/step]
2204 013 Environ. : MM: [C] *EGB [0 to 255 / 179 / 1/step]
2204 014 Environ. : MM: [Y] *EGB [0 to 255 / 176 / 1/step]
2204 016 Environ. : L: [K] *EGB [0 to 255 / 195 / 1/step]
2204 017 Environ. : L: [M] *EGB [0 to 255 / 184 / 1/step]
2204 018 Environ. : L: [C] *EGB [0 to 255 / 184 / 1/step]
2204 019 Environ. : L: [Y] *EGB [0 to 255 / 185 / 1/step]