2252 004 Repeat: [Y]
2302 [Temp./Humidity] Temperature / Humidity Display
2302 001 Temperature
Displays the temperature.
[-128 to 127 / 0 / 0.1 deg/step]
2302 002 Relative Humidity
Display the relative humidity.
[0 to 100 / 0 / 0.1%RH/step]
2302 003 Absolute Humidity
Display the absolute humidity.
[0 to 100 / 0 / 0.1 g/m
3
/step]
2302 004 Current Environ.
Display the current environment.
[0 to 4 / 0 / 1/step]
0: LL, 1: ML, 2: MM, 3: MH, 4: HH
2303 [Envir. Correct.] Environment Correction
2303 001 Manual Correct. *EGB
Manually sets the environment.
[0 to 5 / 0 / 1/step]
0: OFF, 1: LL, 2: ML, 3: MM, 4: MH, 5: HH
2304
[EC Threshold] Environment Correction Threshold
(Humidity, Environment) A. Humidity: Absolute Humidity
These SPs adjust the thresholds (absolute humidity) for each environment.
2304 001 A. Humidity: LL-MM *EGB [0 to 100 / 5.0 / 0.1 g/m
3
/step]
2304 002 A. Humidity: ML-MM *EGB [0 to 100 / 8.0 / 0.1 g/m
3
/step]
2304 003 A. Humidity: MM-MH *EGB [0 to 100 / 16.0 / 0.1 g/m
3
/step]
2304 004 A. Humidity: MH-HH *EGB [0 to 100 / 26.0 / 0.1 g/m
3
/step]
2306 [Vd Link Corre.] Vd Link Correction
2306 001 Setting *EGB
Sets the Vd link correction.
[0 or 1 / 0 / -] Alphanumeric
0: Execute, 1: Not execute