[1 to 3 / 3 / 1 /step]
1: Normal (ON except the line position adjustment
at printout interval)
2: Always ON
3: Always OFF
9911 [TC Initial]
9911 001 Maximum Repeat *EGB
Adjusts the maximum toner cartridge initializing
time.
[1 to 30 / 15 / 1 /step]
9911 002 Threshold *EGB
Adjusts the threshold for toner cartridge initializing.
[1 to 100 / 20 / 0.01 V/step]
9912 [ST Sensor]
9912 001 read *EGB Adjusts the Vcnt. DFU
9914
[Waste Toner NF] Waste Toner Near Full
Specifies the number of sheets to be printed after waste toner near full.
9914 001 Print 1 *EGB [0 to 5000 / 1250 / 1/step]
9914 002 Print 2 *EGB [0 to 5000 / 250 / 1/step]
9914 003 Print 3 *EGB [0 to 5000 / 125 / 1/step]
9914 004 Print 4 *EGB
Specifies the number of sheets to be printed after
replacing the waste toner bottle.
[0 to 5000 / 2500 / 1/step]
9914 005 Detection Times *EGB
Displays the times of waste toner near full.
[0 to 50 / 0 / 1 /step]
9914 006 Near Full Count. *EGB
Displays the total counter for waste toner near full.
[0 to 100000 / 0 / 1 /step]
9918 [LD Pow. Change] LDB Power Change
9918 001 *EGB [0 or 1 / 0 / -] Alphanumeric