System SP5-xxx
SM 5-57 M052/M053/M054
System
Maintenance
Reference
002
CE Call
Performs the CE Call at the start or end of the service.
[0 or 1 / 0 / 1 /step]
0: Start of the service
1: End of the service
NOTE: This SP is activated only when SP 5816-001 is set to "2".
003
Function Flag
Enables or disables the remote service function.
[0 to 1 / 0 / 1 /step]
0: Disabled, 1: Enabled
NOTE: This SP setting is changed to "1" after @Remote registor has been
completed.
007
SSL Disable
Uses or does not use the RCG certification by SSL when calling the RCG.
[0 to 1 / 0 / 1 /step]
0: Uses the RCG certification
1: Does no use the RCG certification
008
RCG Connect Timeout
Specifies the connect timeout interval when calling the RCG.
[1 to 90 / 30 / 1 second /step]
009
RCG Write Timeout
Specifies the write timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
010
RCG Read Timeout
Specifies the read timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]