System SP5-xxx
SM 5-63 M052/M053/M054
System
Maintenance
Reference
151
Line Type Authentication Judgment
Press [Execute].
Setting this SP classifies the telephone line where embedded RCG-M is
connected as either dial-up (pulse dial) or push (DTMF tone) type, so
embedded RCG-M can automatically distinguish the number that connects to
the outside line.
The current progress, success, or failure of this execution can be
displayed with SP5816-152.
If the execution succeeded, SP5816-153 will display the result for
confirmation and SP5816-154 will display the telephone number for the
connection to the outside line.
152
Line Type Judgment Result
Displays a number to show the result of the execution of SP5816 151. Here is
a list of what the numbers mean.
0: Success
1: In progress (no result yet). Please wait.
2: Line abnormal
3: Cannot detect dial tone automatically
4: Line is disconnected
5: Insufficient electrical power supply
6: Line classification not supported
7: Error because fax transmission in progress – ioctl() occurred.
8: Other error occurred
9: Line classification still in progress. Please wait.

Table of Contents