Bit Switches
M381 82 SM
Communication Switch 17 [SP No. 1-104-024]
No FUNCTION COMMENTS
0
SEP reception
0: Disabled
1: Enabled
0: Polling transmission to another maker's
machine using the SEP (Selective Polling) signal
is disabled.
1
SUB reception
0: Disabled
1: Enabled
0: Confidential reception to another maker's
machine using the SUB (Sub-address) signal is
disabled.
2
PWD reception
0: Disabled
1: Enabled
0: Disables features that require PWD (Password)
signal reception.
3-4
Not used
Do not change the settings.
5
PSTN dial-in routing setting
0: OFF
1: ON
1: The machine sets multiple PSTN dial-in number
in the PSTN dial-in lien and transfers received
data of each PSTN dial-in number to each
address.
6
Not used
Do not change the settings.
7
Action when there is no box
with an F-code that matches
the received SUB code
0: Disconnect the line
1: Receive the message
(using normal reception mode)
Change this setting when the customer requires.