NCU Parameters
SM 109 M381
Fax Option
Type SP5200
(M381)
Address Function Unit Remarks
680548 Country dial wait interval (LOW)
680549 Country dial wait interval (HIGH)
68054A
DFU
1 ms
See Notes 3.
SP2-103-012
(parameter 11).
68054B Break time for pulse dialing 1 ms
See Note 3.
SP2-103-013
(parameter 12).
68054C Make time for pulse dialing 1 ms
See Note 3.
SP2-103-014
(parameter 13).
68054D
DFU
1 ms
See Notes 3.
SP2-103-015
(parameter 14).
This parameter is only
valid in Europe.
68054E
Minimum pause between dialed
digits (pulse dial mode)
20 ms
See Note 3.
SP2-103-016
(parameter 15).
68054F
Time waited when a pause is
entered at the operation panel
SP2-103-017
(parameter 16)
680550 DTMF tone on time
1 ms
SP2-103-018
(parameter 17).
680551 DTMF tone off time
SP2-103-019
(parameter 18).
680552 DTMF signal TX level -0.5 dBm
SP2-103-020
(parameter 19).
See Note 5.