Image Fusing
M199/M200/M203/M204 3-56 SM
When Reassembling the Fusing Unit
Route the harness [A] as shown below when reinstalling the back cover [B].
3.10.3 TRANSPORT/FUSING MOTOR
1. Rear cover (page 3-6 "Rear Cover")
2. Left cover (page 3-8 "Left Cover")
3. Disconnect the fusing connector [A] and remove the fusing relay harness [B] (2
hooks).
4. Fusing harness guide [C] ( × 2)
5. Duplex timing belt [D]