SC No.  Level  Error Name/Error Condition/Major Cause/Solution 
203-00  B  Polygon motor: OFF timeout error 
Polygon motor has not stopped when 3 seconds have elapsed 
after the machine turned the polygon motor OFF. 
  The interface harness to the polygon motor driver damaged 
or not connected correctly. 
  Polygon motor or polygon motor driver defective 
  Polygon motor drive pulse cannot be output correctly. 
  Check the harness of the laser unit (disconnected, etc.). 
  Check if the laser unit connector is connected. 
  Check if the PSU 24 V power is output. 
  Replace the interface harness of the laser unit. 
  Replace the laser unit. 
  Replace the MPU. 
  Replace the PSU 
 
SC No.  Level  Error Name/Error Condition/Major Cause/Solution 
204-00  B  Polygon motor: Lock signal error 
An error is detected during the polygon motor rotation. 
  The interface harness to the polygon motor driver damaged 
or not connected correctly. 
  Polygon motor or polygon motor driver defective 
  Check the harness of the laser unit (disconnected, etc.). 
  Check if the laser unit connector is connected. 
  Check if the PSU 24 V power is output. 
  Replace the interface harness of the laser unit. 
  Replace the laser unit. 
  Replace the MPU. 
  Replace the PSU.