SC Code Descriptions 
SM  6-14  D245/D246/D247 
 
SC No.  Level  Error Name/Error Condition/Major Cause/Solution 
392-00  B  Initial developer setting error 
  A read error for the ID sensor pattern at the initial developer 
setting is detected. 
  If the Vsp output is more than 2.5 V, the machine detects 
that there is no developer, and displays SC. 
  ID sensor defective 
  The OPC drum does not rotate. 
  The development roller does not rotate. 
  Replace the ID sensor. 
  Replace the developer. 
  Replace the PCDU. 
 
6.2.4  SC4XX: IMAGE PROCESSING 
 
SC No.  Level  Error Name/Error Condition/Major Cause/Solution 
440-00  B  Image transfer current error 
The machine detects "1" (error) 10 times consecutively when 
monitoring the output error signal every 20 msec (excluding in 
Sleep mode or with the front door open). 
Right door not closed correctly 
PCDU out of position 
HVPS board defective 
HVPS board harness defective 
  Close the right door correctly. 
  Reinstall the PCDU correctly or replace the PCDU. 
  Replace the HVPS board. 
  Replace the harness of the HVPS board.