SC No.  Level  Error Name/Error Condition/Major Cause/Solution 
361-01  B  TD sensor output upper limit error (K) 
TD sensor output:   
The Vt (SP2-220-004) output continuously exceeds the upper 
limit threshold value (SP2-992-001) for the time of the upper 
limit threshold (SP2-992-003). 
TD sensor is not connected correctly. 
  Check if the TD sensor connector is connected. 
  Check the harness of the TD sensor (disconnected, etc.). 
  Replace the development unit if some error is detected. 
 
SC No.  Level  Error Name/Error Condition/Major Cause/Solution 
362-01  B  TD sensor output lower limit error (K) 
TD sensor output:   
The Vt (SP2-220-004) output is continuously below the lower 
limit threshold value (SP2-992-002) for the time of the lower limit 
threshold (SP2-992-004). 
TD sensor is not connected correctly. 
  Check if the TD sensor connector is connected. 
  Check the harness of the TD sensor (disconnected, etc.). 
  Replace the development unit if some error is detected.