Just before reaching warm-up temperature,
the fusing temperature did not rise above
80
o
C within 15.5 sec. after the power relay
switched on.
Fusing thermostat open
Power supply board Defective
Defective connection of the fusing
unit
543 A
Fusing overheat error – software
Fusing thermistor defective
Power supply board defective
The fusing temperature was detected higher
than 235
o
C for longer than 200 ms.
544 A
High temperature detection: Hard
Defective thermister
Defective fusing unit, PSU, engine
board
The thermister detects a high temperature
signal.
545 A
Fusing lamp remains on
Fusing thermistor defective
Power supply board defective
Defective connection of the fusing
unit
The fusing lamp remained on longer than 12
sec. after the fusing unit reached optimum
temperature and the main motor switched off.
546 A
Unstable fusing temperature
Fusing thermistor defective
Power supply board defective
Defective connection of the fusing
unit
During standby, the fusing temperature went
below 60 °C twice or went above 60 °C three
times within 500 ms.
A 60°C increase in fusing temperature was
detected at five 1-sec. intervals within 60 sec.
before reaching fusing temperature.
547 B
Zero cross signal error
Power supply board defective
Defective mains power supply
condition
Zero cross signals of wavelength 50-60 Hz
were not detected within 5 sec after the fusing
relay switched on.
-or-
Zero cross interrupts did not issue at the
prescribed 3 sec. intervals.
4. Troubleshooting