670 D
Engine startup error
The BCU failed to respond within the
prescribed time when the machine is turn on.
Connections between BCU and
controller board are loose,
disconnected, or damaged
Replace the BCU
Replace the controller board
672 D
Controller startup error
After power on, the line between the
controller and the operation panel did not
open for normal operation.
After normal startup, communication with
the controller stopped.
Controller stalled
Controller installed incorrectly
Controller board defective
Operation panel harness
disconnected or defective
687 B
PER-command error
The machine does not receive
PAPI-PER command for specific time, after
PAPI-PES was issued.
Defective controller
688 B
PAPI-PES error
The machine does not receive
PAPI-PES command after paper is in
registration.
Defective controller
Poor communication
817 D
Monitor error
This is a file detection and electronic file
signature check error when the boot loader
attempts to read the self-diagnostic module,
system kernel, or root system files from the
OS Flash ROM, or the items on the SD card
in the controller slot are false or corrupted.
OS Flash ROM data defective;
change the controller firmware
SD card data defective; use another
SD card
819 C
Fatal kernel error
4. Troubleshooting
60
4
SC 671
RTB 14
SC 674
RTB 14

Table of Contents