Troubleshooting
22
1. Unplug the battery from the harness.
2. Measure voltage of the battery with one multimeter.
If the voltage is down of 10V replace the battery.
3. Connect Bosch diagnose software, if the battery has work between 7 to 9
V, supply default defect will appear. Make a DTC Reset on the controller.
Check : With the battery assembled on the bike turn on the key and measure
the voltage level, battery will show 13,8V, if the battery don’t has this voltage the
system don’t charge correctly the 12V battery.