Troubleshooting
33
Fail: We turn the key the dashboard is ON, but we can pass of the START
screen. Dashboard error light is ON. Motorbike doesn’t charge.
Connect diagnosis software to the bike. If drive unit is not connected check
CAN drive unit, check DC/DC 48V connector.
Controller shows the following errors:
0x27 : (CAN) Communication fault btw. VCU and EM, Deleted after T15
reset if fault is inactive,
0xAF : (CAN) Communication fault btw. VCU and EM, Deleted after T15
reset if fault is inactive,