Safety Requirement
1.1 General Safety Summary
Please review the following safety precautions carefully before putting the instrument
int
o operation so as to avoid any personal injury or damage to the instrument and
any product connected to it. To prevent potential hazards, please follow the
instructions specified in this manual to use the instrument properly.
1 Only the exclusive power cord
designed for the instrument and
authorized for use within the
destination countr
y could be
used.
8
Do not operate the instrument
with suspected failures.
2 Ensure that the instrument is
safely grounded.
9 Provide adequate ventilation.
3 Observe all terminal ratings. 10 Do not operate in wet conditions.
4 Use proper overvoltage
protection.
11 Do not operate in an explosive
atmosphere.
5 Do not operate without covers. 12 Keep instrument surfaces clean
and dry.
6 Do not insert objects into the air
outlet.
13 Prevent electrostatic impact.
7 Avoid circuit or wire exposure.
14 Handle with caution.
WARNING
Equipment meeting Class A requirements may not offer adequate protection to broadcast
services within residential environment.
1.2 Safety Notices and Symbols
Safety Notices in this Manual:
WARNING
Indicat
es a potentially hazardous situation or practice which, if not avoided, will result in
serious injury or death.
CAUTION
Indicat
es a potentially hazardous situation or practice which, if not avoided, could result
in damage to the product or loss of important data.
Safety Requirement
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
1
www.calcert.com sales@calcert.com1.888.610.7664
0
5
10
15
20
25
30

Other manuals for Rigol DHO800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DHO800 Series and is the answer not in the manual?

Rigol DHO800 Series Specifications

General IconGeneral
Channels2 or 4 analog channels
Vertical Resolution12-bit
Vertical Sensitivity1 mV/div to 10 V/div
Timebase Range1 ns/div to 1000 s/div
Power Supply100-240 VAC, 50/60 Hz
Waveform Capture Rate1, 000, 000 wfm/s
InterfacesUSB Host, USB Device, LAN
Digital ChannelsOptional 16-channel MSO
Protocols DecodingI2C, SPI, UART, CAN, LIN
Input Impedance1 MΩ
Trigger TypesEdge, Pulse, Video, Slope, Pattern, Duration, Timeout, Runt, Window