Programming Introduction RIGOL
Programming Guide for DS1000CA Series
2-11
3. :DISPlay:PERSist
Command Format:
:DISPlay:PERSist {ON|OFF}
:DISPlay:PERSist?
Function Explanation:
The commands are used to set the waveform persist ON or OFF.
Returned Format:
Query returns “ON” or “OFF”.
Example:
:DISP:PERS ON Set the waveform persist ON
:DISP:PERS? Query returns “ON”
4. :DISPlay:MNUDisplay
Command Format:
:DISPlay:MNUDisplay <time>
:DISPlay:MNUDisplay?
Function Explanation:
The commands are used to set and query the display time of the menu. The
options of <time> are: 1s, 2s, 5s, 10s, 20s or Infinite.
Returned Format:
Query returns 1s, 2s, 5s, 10s, 20s or Infinite.
Example:
:DISP:MNUD 10 Set the display time of the menu as 10s
:DISP:MNUD? Query returns 10s
5. :DISPlay:MNUStatus
Command Format:
:DISPlay:MNUStatus {ON|OFF}