EasyManuals Logo

Rigol DS1000CA Series Programming Guide

Rigol DS1000CA Series
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #93 background imageLoading...
Page #93 background image
Programming Introduction RIGOL
Programming Guide for DS1000CA Series
2-81
Function Explanation:
The commands are used to set and query the position of cursor AY in manual
mode. The range of <value> is 4~194.
Returned Format:
Query returns the set value of <value>.
Example:
:CURS:MANU:CURAY 100 Set position of cursor AY as 100
:CURS:MANU:CURAY? Query returns 100
6. :CURSor:MANUal:CURBX
Command Format:
:CURSor:MANUal:CURBX <value>
:CURSor:MANUal:CURBX?
Function Explanation:
This command is used to set and query the position of cursor BX in manual
mode. The range of <value> is 4~297.
Returned Format:
Query returns the set value of <value>.
Example:
:CURS:MANU:CURBX 100 Set position of cursor BX as 100
:CURS:MANU:CURBX? Query returns 100
7. :CURSor:MANUal:CURBY
Command Format:
:CURSor:MANUal:CURBY <value>
:CURSor:MANUal:CURBY?
Function Explanation:
This command is used to set and query the position of BY in manual mode.

Other manuals for Rigol DS1000CA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1000CA Series and is the answer not in the manual?

Rigol DS1000CA Series Specifications

General IconGeneral
BrandRigol
ModelDS1000CA Series
CategoryTest Equipment
LanguageEnglish

Related product manuals