2. Important Safety Information 2-4. Safety information
20 / 79
2-4. Safety information
This product is a portable single-gas/two-gas monitor to detect gas.
This product uses two AAA alkaline batteries (Toshiba LR03 or Duracell MN2400/PC2400) or two AAA Ni-MH
batteries (Panasonic eneloop (BK-4MCC)) for power supply. Perform battery replacement only in a
non-hazardous area.
<Japanese explosion-proof specifications>
Explosion-proof
construction
Intrinsically safe explosion-proof construction
Explosion-proof
class
Ex ia IIC T4 Ga (Dry cell specifications)
Ex ia IIC T3 Ga (Rechargeable battery specifications)
Ambient
temperature*
-40 °C to +60 °C
Rating Power source: Toshiba LR03 battery × 2 (3 V DC, 1 mA)
Applicable
guidelines
JNIOSH-TR-46-1: 2015
JNIOSH-TR-46-6: 2015
*The ambient temperature refers to temperatures in the range within which explosion-proof performance can be
maintained. It does not imply the temperature range within which the required product performance may be achieved.
For information on the operating temperature range, refer to `10. Product Specifications'.

Other manuals for Riken Keiki 04 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Riken Keiki 04 Series and is the answer not in the manual?

Riken Keiki 04 Series Specifications

General IconGeneral
BrandRiken Keiki
Model04 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals