ProSYS User's Manual 67
Trouble Description LED KP Response
Low
Battery in
Power
Supply
Module
The capacity of the battery is
low or missing and needs to
be recharged or replaced
Zone 9 LED
flashes.
(Requires
the 16-Zone
LED
keypad.)
Contact your dealer.
AC Loss
in Power
Supply
Module
The commercial power has been
interrupted to the Power Supply
modle(s).
Zone 10 LED
flashes.
(Requires
the 16-Zone
LED
keypad.)
Make sure the connection
of this module's transformer
to AC power has not been
disturbed.
Make sure that the outlet
into which the module's
transformer is plugged is
ON.
Bell
Trouble d
Trouble has been detected
in a bell conncted to the main
panel or to the power supply
expander
Zone 11 LED
flashes
(Requires
the 16-Zone
LED
keypad.)
Contact your dealer.
Auxiliary
Power
Failure
auxiliary power from the
optional Power
Supply module(s).
Zone 12 LED
flashes.
(Requires
the 16-Zone
LED
keypad.)
Contact your dealer.
Day Zone
Trouble
A zone designated as a
DAY ZONE has been faulted
during the disarm period.
The
designated
zone flashes.
(Requires
the 16-Zone
LED
keypad.)
Check the integrity of the
indicated zone.