37
Accessories
1 x Omega adapter CL-regular 2 pcs in box (P/N 10980033)
1 x User manual
Optional accessories
(P/N 1305 2405) Mains Cable PowerCon In TRUE1/Schuko, 2m, indoor
(P/N 1305 2406) Mains Cable PowerCon In TRUE1/US, 2m, indoor
(P/N 1305 2407) Mains Cable PowerCon In TRUE1/open ended, 2m, indoor
(P/N 13052445) Mains Cable PowerCon In TRUE1/CEE 16A, 2m, indoor
(P/N 1305 2439) Daisy Chain PowerCon TRUE1 In/Out, EU, 2m, indoor
(P/N 1305 2440) Daisy Chain PowerCon TRUE1 In/Out, US, 2m, indoor
(P/N 13052444) Daisy Chain PowerCon TRUE1 In/Out, EU, 5m, indoor
(P/N 10980690) Frost 0.5° (exchange) assembled
(P/N 10980691) Frost 1° (exchange) assembled
(P/N 10980693) Frost 10° (exchange) assembled
(P/N 10980694) Frost 20° (exchange) assembled
(P/N 109806915 Frost 30° (exchange) assembled
(P/N 10980033) Omega Adaptor CL-regular 2 pcs
(P/N 17030386) Doughty Trigger Clamp
(P/N 99011963) Safety wire 36 kg
10. Maintenance and cleaning
DANGER !
Disconnect from the mains before starting any
maintenance work
Never use alcohol or solvents for cleaning the front lens and covers of the xture
It is absolutely essential that the xture is kept clean and that dust, dirt and smoke-uid residues must not build
up on or within the xture. Otherwise, the xture‘s light output will be signicantly reduced. Regular cleaning will
not only ensure the maximum light output, but will also allow the xture to function reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning uid is recommended, under no circumstances
should alcohol or solvents be used!
Front lens may require weekly cleaning as smoke-uid tends to building up residues, reducing the light output
very quickly. The cooling fans should be cleaned according to the situation (at least annually).
The interior of the head and base should be cleaned at least annually using a vacuum-cleaner.
Periodically clean the air lter placed in the xture base. This air lter is placed under a grille, which is fastened
by means of two magnets.
Use a vacuum cleaner, compressed air or you can wash them and put back dry.
After replacing the air lter, reset the elapsed time counter in the tab "Information" (Information--->Air Filters--->
Elapsed Time).
More complicated maintenance and service operations are only to be carried out by authorized distributors.