10-3-10 CONNECTION OF WIRES
(1) Connect the wires drawn out from the stator to the wires from the control box. (See Fig. 10-39.)
(2) Press the couplers until the locking hook engages securely.
(3) Connect the grounding wire. (See Fig. 10-40.)
Fig. lo-39
Fig. 1 O-40
WIRE CONNECTIONS BETWEEN CONTROL PANEL AND STATOR]
6P coupler
Wire color : Yellow, Red, Green/Yellow, Brown, White
Green/Yell
Brown
Yellow
Red
White
CONTROL PANEL SIDE
STATOR SIDE
0 Earth (Ground) wire : Pin terminal Wire color Green/Yellow
10-3-11 CONTROL PANEL
(1) Put the control panel over the control lever
and secure it with four M5 screws.
(2) Attach the knob to the control lever.
Note :After the couplers and connectors have
been connected and secured
to
the control
panel, secure the wires with a wire band to
the control panel.