_-
11-4
NO
DC
OUTPUT
11-4-1
CHECK
THE
AC OUTPUT.
Check the generator
by
following Step
11-1-1
through Step
11-1-3.
11-4-2
CHECK THE DC
BREAKER.
If the DC breaker turned
off
while charging a bat-
tery, check the cables for short-circuit or connec-
tion in reverse polarity before resetting it on.
NOTE
:
If
the
DC
output is used to charge a large
capacity battery or an over-discharged
battery, an excessive current may flow
causing.
Fig.
11-10
11-4-3
CHECK THE DC
FUSE.
Check the fuse in the fuse holder.
If
the fuse is blown, check for the cause of fuse
blowing, and then replace with a new one.
FUSE:
10A
NOTE
:
If
the
DC
output
is used
to
charge a large
capacity battery or an over-discharged
battery, an excessive current may flow
causing
fuse
blow.
Fig.
17-11
114-4
CHECK THE
WIRING.
Check
all
the wires to be connected correctly.
11-4-5
CHECK THE DIODE
RECTIFIER.
Remove the control panel and check the diode
rectifier with
a
circuit tester.
Refer to Section
9-7
"DIODE
RECTIFIER"
for the
checking procedure.
-
57-