7.
RANGE
OF
APPLICATIONS
Generally, the power rating of an electrical appliance indicates the amount of work that can be done
by
it.
The electric power required for operating an electrical appliance is not always equal to the output watt-
age
of
the appliance. The electrical appliances generally have a label showing their rated voltage, fre-
quency, and power consumption (input wattage). The power consumption of an electrical appliance is
the power necessary for using
it.
When using a generator for operating an electrical appliance, the power
factor and starting wattage must be taken into consideration.
In order to determine the right size generator, it is necessary to add the total wattage
of
all
appliances to
be connected to the unit.
Refer
to
the followings to calculate the power consumption of each appliance or equipment by its type.
(1)
Incandescent lamp, heater, etc. with a power factor of
1.0
Total power consumption must be equal to or less than the rated output of the generator.
Example
:
A
rated
3000W
generator can turn thirty 1
OOW
incandescent lamps on.
(2)
Fluorescent lamps, motor driven tools, light electrical appliances, etc. with a smaller power
factor
Select
a
generator with
a
rated output equivalent to
1.2
to
2
times
of
the power consumption of the
load. Generally the starting wattage of motor driven tools and light electrical appliances are
1.2
to
3
times lager than their running wattage.
Example
:
A
rated 250
W
electric drill requires a
400
W
generator to
start
it.
NOTEl
:
If a power factor correction capacitor is not applied to the fluorescent lamp, the more power
shall
be
required to drive the lamps.
NOTE2
:
Nominal wattage of the fluorscent lamp generally indicates the output wattage of the lamp.
Therefore,
if
the fluorescent lamp has no special indication as to the power consumption, efi-
ciency should be taken into account as explained in Item
(5)
on
the following page.
(3)
Mercury lamps with a smaller power factor
Loads for mercury lamps require
2
to
3
times the indicated wattage during start-up.
Example
:
A
400
W
mercury lamp requires
800
W
to 1200
W
power source to be turned on.
A
rated
3000
W
generator can power
two
or three
400
W
mercury lamps.
(4)
Initially loaded motor driven appliances such as water pumps, compressors, etc.
These appliances require large starting wattage which is 3 to
5
times of running wattage.
Example
:
A
rated
900
W
compressor requires a
4500
W
generator to drive it.
NOTEl
:
Motor-driven appliances require the aforementioned generator output only at the starting. Once
their motors are started, the appliances consume about
1.2
to
2
times their rated power con-
sumption
so
that the excess power generated
by
the generator can be used for other electrical
appliances.
NOTE2
:
Motor-driven appliances mentioned in items
(3)
and
(4)
vary in their required motor starting
power depending on the kind of motor and start-up load.
If
it is difficult to determine the optimum
generator capacw, select a generator with
a
larger capacity
-
23-

Other manuals for Robin RGV2800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Robin RGV2800 and is the answer not in the manual?

Robin RGV2800 Specifications

General IconGeneral
BrandRobin
ModelRGV2800
CategoryPortable Generator
LanguageEnglish

Related product manuals