Rockwell Automation Publication 440G-UM001B-EN-P - May 2016 21
Installation and Wiring Chapter 3
Use the following table to determine if the extended shaft is needed
(442G-MABASHFT ordered separately) to prepare the escape release for
smaller or larger profiles.
1
Shaft length that is required when only one mounting plate is used.
2
Shaft length that is required when two mounting plates are used for the escape release and the handle
assembly.
3
The extended shaft (442G-MABASHFT) must be ordered separately.
Figure 8 - Example with Mounting Plates [mm (in.)]
IMPORTANT The length of the actuation shaft (115 mm (4.53 in.)) is optimized for
mounting on 40 mm (1.57in.) and 45mm (1.77in.) profiles. For mounting
on profiles larger than 45 mm (or if using mounting plates on a 45mm
profile), an extended shaft is required (order separately, 442G-MABASHFT).
See the table below for instructions about sizing the extended shaft and
mounting the escape release on smaller or larger profiles.
Profile
Width
Length Required for
Actuation Shaft
Shaft Required?
3
Necessary Work Steps
Without
Mounting
Plates
With Mounting
Plates
(4 mm each)
D D+13.5 D + 17.5
1
D+21.5
2
30 mm 43 mm 51 mm Standard shaft Shorten to required length
40 mm 53 mm 61 mm Standard shaft or
extended shaft
• Without mounting plates: shorten
standard shaft to required length
• With two mounting plates: Shorten
extended shaft and protective sleeve
to required length
45 mm 58 mm 66 mm Standard shaft or
extended shaft
• Without mounting plate: none
• With mounting plates: shorten
extended shaft and protective sleeve
to required length
50 mm 63 mm 71 mm Extended shaft Shorten extended shaft and protective
sleeve to required length
4
(0.16)
D
10
(0.39)
3.5
(0.14)
4
(0.16)
58.5
(2.30)
Handle module
Mounting plates
Escape release assembly