Note 1: K1 and K2 - 100S-CO9EJ14BC:
EJ contactors have integral transient suppression.
External transient suppressions may be required
when non=”EJ” contactors are used.
Note 2: U : Connected to 24V internally in MAB
OL: True when the door is closed, the bolt is extended and locked.
OT: True when the door is closed and the bolt is extended, locked or not.
Note 3: When using a Hardware Rev. A MAB, connect the violet wire to terminal 51 of the 
GLT. The gray/brown wire must remain unconnected.
Note that the terminal designations of X3.6 and X3.7 are different on Hardware 
Rev. A and Hardware Rev. B MAB.
A
In this example The E-stop initiates a category 1 stop function.
The unlock request provides a category 1 stop function.
The MAB and GLP provide a speed monitored guard lock function.
The MAB and GLP provide a prevention of unexpected start-up function.
Hardware Rev. B
MAB cover
Reset/Lock
Blue
Brown
Yel lo w/
Brown
Green/
Black
Red/Blue
Unlock Cmd A
- see Note 2
Unlock Cmd B
Violet
Gray/Brown
White/Green
Pink
Blue
Black
Brown
Blue
Black
Brown
- see Note 3
White
Gray/Pink
Reset MAB
MAB cover
Unlock Request
Stop
Start
- see Note 1
Rev. BRev. A