In this example The unlock request initiates a category 1 stop.
The MAB and GLT provide a time delayed guard lock function.
The MAB and GLT provide a prevention of unexpected start-up function.
Hardware Rev. B
Safe Torque-off (STO)
Connector with
D Wiring Header
- see Note 2
Time
Blue
LOGIC*
(IOD) Connector
Brown
Range
Unlock Request
White
Reset/Lock
Green/Black
Red/Blue
Unlock Cmd A
Digital Input
Unlock Cmd B
Violet
Gray/Brown
Note 1: When using a Hardware Rev. A MAB, connect the violet wire to terminal
51 of the GLT. The gray/brown wire must be remain unconnected.
Note that the terminal designations for X3.6 and X3.7 are different on
Hardware Rev. A and Hardware Rev. B MAB.
Gray/Pink
- see Note 1
MAB Reset/Lock
Safety Input 1
Status
Safety Input 2
Safety Common
Note 2: The digital input configured for Abort Index in MotionView software, must be
active-high when the safety function is requested. Digital input common
(IN_x_COM) must be used in this signal activation/de-activation transition.
Rev. A Rev. B