EasyManua.ls Logo

Rockwell Automation Allen-Bradley PowerFlex 755TS TotalFORCE Control - Page 43

Rockwell Automation Allen-Bradley PowerFlex 755TS TotalFORCE Control
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rockwell Automation Publication 750-IN119A-EN-P - April 2022 43
Chapter 3 Prepare for Installation
Figure 23 - IP00, NEMA/UL Open Type, Wall Mount Frames 6 and 7 (Frame 6 Shown)
Dimensions are in millimeters and (inches).
Frame 6: M6 (#12) mounting hardware recommended.
Frame 7: M8 (5/16 in.) mounting hardware recommended.
GE
F
D
C
6.4 (0.25)
14.5 (0.57)
A
B
ø6.5 (0.26)
ø14.5 (0.57)
6
7
8.5 (0.33)
25.0 (0.98)
ø8.5 (0.33)
ø16.0 (0.63)
Frame A B C D E F G Weight [kg (lb)]
6
308.0
(12.13)
665.5
(26.20)
346.4
(13.64)
283.0
(11.14)
623.0
(24.53)
254.0
(10.00)
609.0
(23.98)
48.0
(105.0)
7
430.0
(16.93)
881.5
(34.70)
349.6
(13.76)
380.0
(14.96)
838.0
(32.99)
330.0
(12.99)
825.0
(32.48)
82.0
(180.0)
IMPORTANT Always install mounting hardware in all four
corners of the mounting legs for stability.
Only install mounting hardware through the
top key holes to help make sure that the
drive is securely fastened to the mounting
surface.
At the bottom of the mounting legs, either
the key holes or optional open mounting
slots can be used.

Related product manuals