b) While the system / partition A is disarmed:
• OFF
• ON – while the master user is being within master user’s menu of program/modify
the user codes, “follow-me” phone numbers or system date and hour;
• ON - while the installer is being within programming menu of the system
parameters.
ARMED B LED
a) While the partition B is armed:
• ON – if the partition B is totally armed;
• Fast Blinking – if the partition B is armed in “instant stay mode”.
• Slow Blinking – if the partition B is armed in “stay mode”.
b) While the partition B is disarmed: OFF
Zone LEDs
a) While the system is completely armed:
• ON – the corresponding zone triggered the alarm at least once during that arming
period;
• BLINK – the corresponding zone tamper triggered the alarm at least once during
that arming period;
b) While the system is completely disarmed or partial armed:
• OFF – the loop of corresponding zone is closed;
• ON – the loop of corresponding zone is faulted.
• While the system finds itself within one of the programming/displaying menus:
o ON – the user is being within one the zone bypassing menu and the respective
zone is bypassed;
o ON/OFF – they are displaying certain parameters’ status (activate/deactivate)
– while the installer is being within certain sections of programming menu of
the system parameters.