While the system is within programming / erasing session of the „selected user code”, the keypad
LEDs’ status will be as follows:
Keypad LEDs:
LEDs’ Status:
Remarks:
entering.
Only zone 1 LED
Blinking
Means the „selected user code” isn’t programmed and the control
panel is waiting for the first digit entering.
One of the 2 to 4 zone
LEDs
Blinking
Means the „selected user code” is programming and the control
panel is waiting for the corresponding digit.
1. Programming/Erasing of the „selected user code” may be skipped by [#] key
pressing.
1.1 After [#] key pressing, if the selected user code was programmed during a
previous programming session, the keypad buzzer will sound 3 confirmation beeps and the
system will pass to display the rights of the selected user code(step no. 3).
1.2 After [#] key pressing, if the „selected user code” wasn’t programmed
during a previous programming session, the keypad buzzer will sound 6 confirmation beeps
and the control panel will go back within „master user’s programming menu”.
2. In order to program the selected user code”, you should enter the following
sequence from the keypad:
[x][x][x][x], where [x][x][x][x] are the new 4 digits for the „selected user code”.
2.1 After entering the first digit the zone 2 LED will blink. Means the control panel is
waiting for the second digit.
2.2. After entering second digit the zone 3 LED will blink. Means the control panel is
waiting for the third digit.
2.3. After entering third digit the zone 4 LED will blink. Means the control panel is
waiting for the fourth digit.
2.4. After any digit was pressed, programming of the „selected user code” may be
canceled by [#] key pressing. After cancellation by [#] key pressing, the keypad buzzer
will sound 6 confirmation beeps, the system will keep the old value for the „selected user
code” and the control panel will go back within „master user’s programming menu”.
Note: Do not press [*] key while entering the digits of the „selected user code”! The keypad buzzer will sound a long
error beep, will reject [*] key and will go back within „master user’s programming menu”.
3. After entering the last digit of the „selected user code” the keypad buzzer will sound
3 confirmation beeps and the panel will pass to the next step, displaying on zone 1 to 7
LEDs the RIGHTS set of the just modified „user code”, as follows:
Keypad LEDs’ status while the system is within RIGHTS displaying submenu
for „selected user code”:
ARMED A LED
ON
SYSTEM LED
Blinking
READY A LED
ON
Zone LEDs
ON
OFF
zone 1 LED
enabled
*
disabled
Zone bypassing
zone 2 LED
enabled
*
disabled
Regular arming
zone 3 LED
enabled
disabled
*
Stay arming
zone 4 LED
enabled
disabled
*
Force arming
zone 5 LED
enabled
disabled
*
Disarming/siren stopping
zone 6 LED
enabled
*
disabled
Access to partition A
zone 7 LED
enabled
disabled
*
Access to partition B
zone 8 LED
enabled
disabled
*
reserved
By [#] key pressing, RIGHTS set of the just modified „user code” can be maintained as it
was previously established.
3.1 In order to turn activate/deactivate each right display-able on zone 1 to 7 LEDs,
you should press the 1 to 7 keys and the appropriate zone LED will turn ON/OFF. If the zone
LED is ON means the appropriate right is enabled and if the zone LED is OFF means the right
is disabled.
3.2 Finally you should press [#] key to confirm the RIGHTS set of the respective
user code. After [#] key pressing, the keypad buzzer will sound 6 confirmation beeps and
the control panel will go back within „master user’s programming menu”.