103
Chapter 7 Making the MIDI Settings (SETUP/MIDI, BULK DUMP)
7
fig.07-023ai.e
Part CH (Part Tx Rx Channel): CH 1–CH16, OFF
MIDI Messages Stop Function 
for Specific Parts in GM 
(General MIDI) Mode (GM PART)
In GM mode, you can make the setting that determines 
whether or not MIDI messages are to be received for each 
individual part.
When set to “OFF,” that part’s MIDI messages are not 
received.
1. While holding down [SHIFT], press [EDIT 
(SETUP)].
[EDIT] lights.
2. Press [ ] to select “GM PART.”
fig.SETUP-GMPRT_50 (SETUP-MIDI PART) 
When “GM Mode” is set to “OFF,” “MIDI PART” is displayed, 
and you cannot make the setting.
Make the setting after first setting “GM Mode” to “ON” 
(SETUP/MIDI COMMON/GM Mode; p. 100).
3. Press [ENTER ].
4. Press [ ] or [ ] to select the part to be set.
fig.07-024ai.e
5. Press [INC/+] or [DEC/-] to make the setting.
fig.07-025ai.e
6. When you finish making settings, press [KIT] to 
end the procedure.
Part Rx Sw (Part Rx Switch): OFF, ON
Saving Data to an External MIDI 
Device (BULK DUMP)
You can save the TD-6’s drum kits, songs, general settings, 
and more to an external MIDI sequencer.
use the external sequencer as you would when recording 
musical data, and perform the following steps on the TD-6 as 
shown in the following diagram.
Bulk Dump is one kind of System Exclusive message. Be sure 
to use an external MIDI sequencer that is capable of recording 
System Exclusive messages. In addition, confirm that the 
sequencer is not set to “Do not receive System Exclusive 
messages.”
Setting the Device ID (SETUP/MIDI COMMON/DeviceID; p. 
101) makes operation more convenient when multiple TD-6’s 
are connected.
For more detailed information concerning external MIDI 
devices, be sure to read the owner’s manuals for the devices 
you are using.
1. Use a MIDI cable to connect the TD-6’s MIDI 
OUT connector to the MIDI IN connector of the 
external sequencer.
fig.07-026.e
2. While holding down [SHIFT], press [EDIT 
(SETUP)].
[EDIT] lights.
3. Press [ ] to select “BULK DUMP.”
fig.SETUP-BULK_50 (SETUP-BULK DUMP) 
4. Press [ENTER ].
Value
Select Part
Value
TD-6
MIDI OUT MIDI IN
External MIDI Sequencer