Factory settings
UPT-640 (as of SW 100) 51
10 Factory settings
The CIRUS temperature controller UPT-640 (as of SW
100) is configured in the factory as follows:
Values in the Settings
and Configuration
menus
Settings menu
No. 101 Heatsealing temperature:0°C
No. 102 Preheating temperature: 0°C
No. 103 Starting delay: 0s
No. 104 Heatsealing time: 0.10s
No. 105 Cooling value: Cooling time: 1.00 s
Absolute cooling temperature: 50°C
Relative cooling temperature:
40 % of heatsealing temperature
No. 106 Hold mode: OFF
No. 107 AUTOCAL temperature: 20°C
No. 110 Correction factor Co: 100%
No. 115 Release temperature: 0°C
No. 116 Release delay. 0s
No. 117 Release duration: 0s
Configuration menu
No. 201 Language German
This selection is NOT changed if the factory settings are
restored with step 202 in the Config. menu.
No. 203 Alloy 1700ppm
No. 204 Temperature range: max. 300°C
No. 206 Maximum temperature: 300°C
No. 207 Set point reached: -10K
No. 208 Set point exceeded: +10K
No. 209 Time control: OFF
No. 210 Cooling mode: Absolute
No. 212 Relay K1 function: Active when temperature reached
No. 213 Lock of „HAND“ key OFF
No. 214 Cycle counter: 0
No. 215 Alarm relay: Normal (contact closed by a fault)
No. 216 Analog output: Actual temperature
No. 217 Temperature diagnosis: OFF
No. 218 Temp.diagnosis
delay time: 0s
No. 219 Heatup timeout: OFF
No. 220 Measuring impulse length:Standard (1.7ms)
No. 221 Autocomp: OFF
No. 222 "Output 1": Active if Tact = Tset, with latch function
No. 224 Starting temperature: 100°C
No. 225 Temperature unit: Celsius